首页 » 文章 » 文章详细信息
International Journal of Dentistry Volume 2019 ,2019-07-07
Comparison of Overall Fit of Milled and Laser-Sintered CAD/CAM Crown Copings
Research Article
Lucie Zuskova 1 Noor A. Al Mortadi 2 Robert J. Williams 1 Karem H. Alzoubi 3 Omar F. Khabour 4
Show affiliations
DOI:10.1155/2019/7310175
Received 2019-02-12, accepted for publication 2019-06-26, Published 2019-06-26
PDF
摘要

Background and Aims. The aim of this study was to investigate the effect of computer-aided design/computer-aided manufacturing (CAD/CAM) procedures on the overall fit of metal copings. Materials and Methods. A standardized die was made in die stone of an upper right molar prepared for a full crown. The die was digitalized by an Identica Blue Light Scanner, and the coping substructure was designed using CAD software. Ten milled specimens and ten laser-sintered specimens were manufactured by Renishaw plc based on the generated file by the software. All twenty copings were digitized by the Identica scanner, and the data were superimposed with the original premanufacturing data file of the prepared full crown. Using the Geometric Modelling Library (GML) package, the fit discrepancies were displayed as colour maps showing discrepancies in three dimensions. Each map was made up of thousands of data points carrying numerical error values allowing detailed analyses. Results. The milled group displayed a mean of fit discrepancies of 42.20 μm (SD 3.04 μm), while the laser-sintered group showed a mean of 42.24 μm fit discrepancies (SD 2.94 μm). Thus, a small difference of 0.04 μm between the two groups was detected. Conclusions. The evaluated manufacturing systems can be used in dental practice as a small and insignificant discrepancy of fit between the two manufacturing methods was detected.

授权许可

Copyright © 2019 Lucie Zuskova et al. 2019
This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

通讯作者

Noor A. Al Mortadi.Department of Applied Dental Sciences, Jordan University of Science and Technology, Faculty of Applied Medical Sciences, Irbid, Jordan, just.edu.jo.nooralmortadi@gmail.com

推荐引用方式

Lucie Zuskova,Noor A. Al Mortadi,Robert J. Williams,Karem H. Alzoubi,Omar F. Khabour. Comparison of Overall Fit of Milled and Laser-Sintered CAD/CAM Crown Copings. International Journal of Dentistry ,Vol.2019(2019)

您觉得这篇文章对您有帮助吗?
分享和收藏
0

是否收藏?

参考文献
[1] T. Nakamura, N. Dei, T. Kojima, K. Wakabayashi. et al.(2003). Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns. International Journal of Prosthodontics.16(3):244-248. DOI: 10.1038/sj.bdj.2008.350.
[2] D. Grauer, D. Wiechmann, G. C. Heymann, E. J. Swift. et al.(2012). Computer-aided design/computer-aided manufacturing technology in customized orthodontic appliances. Journal of Esthetic and Restorative Dentistry.24(1):3-9. DOI: 10.1038/sj.bdj.2008.350.
[3] P. Dérand, L.-E. Rännar, J.-M. Hirsch. (2012). Imaging, virtual planning, design, and production of patient-specific implants and clinical validation in craniomaxillofacial surgery. Craniomaxillofacial Trauma and Reconstruction.5(3):137-144. DOI: 10.1038/sj.bdj.2008.350.
[4] K.-B. Kim, J.-H. Kim, W.-C. Kim, H.-Y. Kim. et al.(2013). Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques. Journal of Advanced Prosthodontics.5(2):179-186. DOI: 10.1038/sj.bdj.2008.350.
[5] R. Van Noort. (2012). The future of dental devices is digital. Dental Materials.28(1):3-12. DOI: 10.1038/sj.bdj.2008.350.
[6] Y. Ucar, T. Akova, M. S. Akyil, W. A. Brantley. et al.(2009). Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns. Journal of Prosthetic Dentistry.102(4):253-259. DOI: 10.1038/sj.bdj.2008.350.
[7] O. Schaefer, H. Kuepper, G. A. Thompson, G. Cachovan. et al.(2013). Effect of CNC-milling on the marginal and internal fit of dental ceramics: a pilot study. Dental Materials.29(8):851-858. DOI: 10.1038/sj.bdj.2008.350.
[8] T. Akova, Y. Ucar, A. Tukay, M. C. Balkaya. et al.(2008). Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain. Dental Materials.24(10):1400-1404. DOI: 10.1038/sj.bdj.2008.350.
[9] S. H. Huang, P. Liu, A. Mokasdar, L. Hou. et al.(2013). Additive manufacturing and its societal impact: a literature review. International Journal of Advanced Manufacturing Technology.67(5–8):1191-1203. DOI: 10.1038/sj.bdj.2008.350.
[10] K. Quante, K. Ludwig, M. Kern. (2008). Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology. Dental Materials.24(10):1311-1315. DOI: 10.1038/sj.bdj.2008.350.
[11] G. Farronato, G. Santamaria, P. Cressoni, D. Falzone. et al.(2011). The digital-titanium herbst. Journal of Clinical Orthodontics.45(5):263-267. DOI: 10.1038/sj.bdj.2008.350.
[12] V. Harish, S. A. Mohamed Ali, N. Jagadesan. (2014). Evaluation of internal and marginal fit of two metal ceramic system-in vitro study. Journal of Clinical and Diagnostic Research.8(12):53-56. DOI: 10.1038/sj.bdj.2008.350.
[13] T. Miyazaki, Y. Hotta, J. Kunii, S. Kuriyama. et al.(2009). A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dental Materials Journal.28(1):44-56. DOI: 10.1038/sj.bdj.2008.350.
[14] A. A. Nasef, A. R. El-Beialy, Y. A. Mostafa. (2014). Virtual techniques for designing and fabricating a retainer. American Journal of Orthodontics and Dentofacial Orthopedics.146(3):394-398. DOI: 10.1038/sj.bdj.2008.350.
[15] T. Traini, C. Mangano, R. L. Sammons, F. Mangano. et al.(2008). Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants. Dental Materials.24(11):1525-1533. DOI: 10.1038/sj.bdj.2008.350.
[16] W. T. Buchanan, C. W. Svare, K. A. Turner. (1981). The effect of repeated firings and strength on marginal distortion in two ceramometal systems. Journal of Prosthetic Dentistry.45(5):502-506. DOI: 10.1038/sj.bdj.2008.350.
[17] M. Vojdani, K. Torabi, E. Farjood, A. Khaledi. et al.(2013). Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD/CAM and conventional wax up techniques. Journal of Dentistry, Shiraz University of Medical Sciences.14(3):118-119. DOI: 10.1038/sj.bdj.2008.350.
[18] N. Al Mortadi, D. Eggbeer, J. Lewis, R. J. Williams. et al.(2013). Design and fabrication of a sleep apnea device using computer-aided design/additive manufacture technologies. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine.227(4):350-355. DOI: 10.1038/sj.bdj.2008.350.
[19] M. C. Goiato, M. R. Santos, A. A. Pesqueira, A. Moreno. et al.(2011). Prototyping for surgical and prosthetic treatment. Journal of Craniofacial Surgery.22(3):914-917. DOI: 10.1038/sj.bdj.2008.350.
[20] A. Bindl, W. H. Mormann. (2003). Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns. European Journal of Oral Sciences.111(2):163-169. DOI: 10.1038/sj.bdj.2008.350.
[21] B. P. Issenberg, M. E. Essig, K. F. Leinfelder. (1992). Three-year clinical evaluation of CAD-CAM restorations. Journal of Esthetic and Restorative Dentistry.4(5):173-176. DOI: 10.1038/sj.bdj.2008.350.
[22] F. Beuer, J. Schweiger, D. Edelhoff. (2008). Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. British Dental Journal.204(9):505-511. DOI: 10.1038/sj.bdj.2008.350.
[23] . DOI: 10.1038/sj.bdj.2008.350.
[24] M. R. Baig, K. B.-C. Tan, J. I. Nicholls. (2010). Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system. Journal of Prosthetic Dentistry.104(4):216-227. DOI: 10.1038/sj.bdj.2008.350.
[25] A. Ortrop, D. Jonsson, A. Mouhsen, P. V. von Steyern. et al.(2011). The fit of cobalt–chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dental Materials.27(4):356-363. DOI: 10.1038/sj.bdj.2008.350.
[26] J. W. McLean, F. von. (1971). The estimation of cement film thickness by an in vivo technique. British Dental Journal.131(3):107-111. DOI: 10.1038/sj.bdj.2008.350.
[27] S. Giannetopoulos, R. van Noort, E. Tsitrou. (2010). Evaluation of the marginal integrity of ceramic copings with different marginal angles using two different CAD/CAM systems. Journal of Dentistry.38(12):980-986. DOI: 10.1038/sj.bdj.2008.350.
文献评价指标
浏览 4次
下载全文 0次
评分次数 0次
用户评分 0.0分
分享 0次