首页 » 文章 » 文章详细信息
Abstract and Applied Analysis Volume 2013 ,3013-03-31
Voltage Stability Bifurcation Analysis for AC/DC Systems with VSC-HVDC
Research Article
Yanfang Wei 1 Zheng Zheng 1 Yonghui Sun 2 Zhinong Wei 2 Guoqiang Sun 2
Show affiliations
DOI:10.1155/2013/387167
Received 2013-01-24, accepted for publication 2013-03-01, Published 2013-03-01
PDF
摘要

A voltage stability bifurcation analysis approach for modeling AC/DC systems with VSC-HVDC is presented. The steady power model and control modes of VSC-HVDC are briefly presented firstly. Based on the steady model of VSC-HVDC, a new improved sequential iterative power flow algorithm is proposed. Then, by use of continuation power flow algorithm with the new sequential method, the voltage stability bifurcation of the system is discussed. The trace of the P-V curves and the computation of the saddle node bifurcation point of the system can be obtained. At last, the modified IEEE test systems are adopted to illustrate the effectiveness of the proposed method.

授权许可

Copyright © 2013 Yanfang Wei et al. 2013
This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

图表
通讯作者

Yanfang Wei.School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454000, China, hpu.edu.cn.weiyanfang@hpu.edu.cn

推荐引用方式

Yanfang Wei,Zheng Zheng,Yonghui Sun,Zhinong Wei,Guoqiang Sun. Voltage Stability Bifurcation Analysis for AC/DC Systems with VSC-HVDC. Abstract and Applied Analysis ,Vol.2013(3013)

您觉得这篇文章对您有帮助吗?
分享和收藏
0

是否收藏?

参考文献
[1] X. Wang, Y. Song, M. Irving. (2008). Modern Power Systems Analysis. DOI: 10.1109/TIE.2010.2049719.
[2] U. Arifoglu. (2003). The power flow algorithm for balanced and unbalanced bipolar multiterminal ac-dc systems. Electric Power Systems Research.64(3):239-246. DOI: 10.1109/TIE.2010.2049719.
[3] M. P. Bahrman, B. K. Johnson. (2007). The ABCs of HVDC transmission technologies. IEEE Power and Energy Magazine.5(2):32-44. DOI: 10.1109/TIE.2010.2049719.
[4] H. F. Latorre, M. Ghandhari, L. Söder. (2008). Active and reactive power control of a VSC-HVdc. Electric Power Systems Research.78(10):1756-1763. DOI: 10.1109/TIE.2010.2049719.
[5] Power Systems Test Case Archive. University of Washington. . DOI: 10.1109/TIE.2010.2049719.
[6] L. Zhang, H. P. Nee, L. Harnefors. (2011). Analysis of stability limitations of a VSC-HVDC link using power-synchronization control. IEEE Transactions on Power Systems.26(3):1326-1337. DOI: 10.1109/TIE.2010.2049719.
[7] C. Angeles-Camacho, O. L. Tortelli, E. Acha, C. R. Fuerte-Esquivel. et al.(2003). Inclusion of a high voltage DC-voltage source converter model in a Newton-Raphson power flow algorithm. IEE Proceedings: Generation, Transmission and Distribution.150(6):691-696. DOI: 10.1109/TIE.2010.2049719.
[8] C. Liu, B. Zhang, Y. Hou, F. F. Wu. et al.(2011). An improved approach for AC-DC power flow calculation with multi-infeed DC systems. IEEE Transactions on Power Systems.26(2):862-869. DOI: 10.1109/TIE.2010.2049719.
[9] F. L. Shun, M. Reza, K. Srivastava, S. Cole. et al.Influence of VSC HVDC on transient stability: case study of the Belgian grid. . DOI: 10.1109/TIE.2010.2049719.
[10] H. Livani, J. Rouhi, H. Karirni-Davijani. Voltage stabilization in connection of wind farms to transmission network using VSC-HVDC. . DOI: 10.1109/TIE.2010.2049719.
[11] Y. Jiang-Häfner, M. Hyttinen, B. Pääjärvi. On the short circuit current contribution of HVDC light. . DOI: 10.1109/TIE.2010.2049719.
[12] S. Kouro, M. Malinowski, K. Gopakumar, J. Pou. et al.(2010). Recent advances and industrial applications of multilevel converters. IEEE Transactions on Industrial Electronics.57(8):2553-2580. DOI: 10.1109/TIE.2010.2049719.
[13] C. Guo, C. Zhao. (2010). Supply of an entirely passive AC network through a double-infeed HVDC system. IEEE Transactions on Power Electronics.25(11):2835-2841. DOI: 10.1109/TIE.2010.2049719.
[14] A. Pizano-Martinez, C. R. Fuerte-Esquivel, H. Ambriz-Pérez, E. Acha. et al.(2007). Modeling of VSC-based HVDC systems for a Newton-Raphson OPF algorithm. IEEE Transactions on Power Systems.22(4):1794-1803. DOI: 10.1109/TIE.2010.2049719.
[15] C. Zheng, X. X. Zhou, R. M. Li. (2005). Dynamic modeling and transient simulation for voltage source converter based HVDC. Power System Technology.29(16):1-5. DOI: 10.1109/TIE.2010.2049719.
[16] V. Ajjarapu, C. Christy. (1992). The continuation power flow: a tool for steady state voltage stability analysis. IEEE Transactions on Power Systems.7(1):416-423. DOI: 10.1109/TIE.2010.2049719.
[17] S. H. Li, H. D. Chiang. (2008). Continuation power flow with nonlinear power injection variations: a piecewise linear approximation. IEEE Transactions on Power Systems.23(4):1637-1643. DOI: 10.1109/TIE.2010.2049719.
[18] J. Zhang, G. Bao. Voltage stability improvement for large wind farms connection based on VSC-HVDC. . DOI: 10.1109/TIE.2010.2049719.
[19] N. Flourentzou, V. G. Agelidis, G. D. Demetriades. (2009). VSC-based HVDC power transmission systems: an overview. IEEE Transactions on Power Electronics.24(3):592-602. DOI: 10.1109/TIE.2010.2049719.
[20] F. A. R. Al Jowder, B. T. Ooi. (2004). VSC-HVDC station with SSSC characteristics. IEEE Transactions on Power Electronics.19(4):1053-1059. DOI: 10.1109/TIE.2010.2049719.
[21] X. P. Zhang. (2004). Multiterminal voltage-sourced converter-based HVDC models for power flow analysis. IEEE Transactions on Power Systems.19(4):1877-1884. DOI: 10.1109/TIE.2010.2049719.
[22] T. Smed, G. Andersson, G. B. Sheble, L. L. Grigsby. et al.(1991). A new approach to AC/DC power flow. IEEE Transactions on Power Systems.6(3):1238-1244. DOI: 10.1109/TIE.2010.2049719.
[23] L. C. Azimoh, K. Folly, S. P. Chowdhury, S. Chowdhury. et al.Investigation of voltage and transient stability of HVAC network in hybrid with VSC-HVDC and HVDC link. :1-6. DOI: 10.1109/TIE.2010.2049719.
[24] L. Zhang, L. Harnefors, H. P. Nee. (2011). Interconnection of two very weak AC systems by VSC-HVDC links using power-synchronization control. IEEE Transactions on Power Systems.26(1):344-355. DOI: 10.1109/TIE.2010.2049719.
[25] Y. Gao, Z. Wang, H. Ling. Available transfer capability calculation with large offshore wind farms connected by VSC-HVDC. . DOI: 10.1109/TIE.2010.2049719.
[26] H. F. Latorre, M. Ghandhari. (2011). Improvement of power system stability by using a VSC-HVdc. International Journal of Electrical Power and Energy Systems.33(2):332-339. DOI: 10.1109/TIE.2010.2049719.
[27] H. F. Latorre, M. Ghandhari. Improvement of voltage stability by using VSC-HVdc. . DOI: 10.1109/TIE.2010.2049719.
[28] Z. Huang, B. T. Ooi, L. A. Dessaint, F. D. Galiana. et al.(2003). Exploiting voltage support of voltage-source HVDC. IEE Proceedings: Generation, Transmission and Distribution.150(2):252-256. DOI: 10.1109/TIE.2010.2049719.
文献评价指标
浏览 1648次
下载全文 220次
评分次数 0次
用户评分 0.0分
分享 0次